Issue Alert Help & FAQ Search Current Issue
ENTH Navbar



[Full-text Article] [PDF Version] [Create Reference]
[PubMed Citation] [Related Articles in PubMed]

Abstract


doi: 10.1583/04-1291MR.1
Journal of Endovascular Therapy: Vol. 11, No. 6, pp. 621–626.

Percutaneous AAA Repair: Is It Safe?

Gabriel Börner, MD1; Krasnodar Ivancev, MD, PhD2; Björn Sonesson, MD, PhD1,2; Bengt Lindblad, MD, PhD1; Dennis Griffin, MD3; and Martin Malina, MD, PhD1,2

1Department of Vascular Surgery, Lund University, Malmö, Sweden

2Department of Radiology, Lund University, Malmö, Sweden

3Department of Radiology Imaging Associates, Radiology Department, Columbia Swedish Medical Center, Englewood, Colorado, USA



Purpose: To assess if percutaneous insertion of large-bore sheaths is safe during endovascular repair (EVR) for abdominal aortic aneurysms (AAA).

Methods: Ninety-five AAA patients undergoing EVR had the endografts implanted percutaneously via 14-F to 20-F sheaths in a prospective nonrandomized study. Vascular sutures were applied bilaterally to the common femoral arteries using a vascular closure device; the sutures were tied after sheath withdrawal. Blood loss, operative time, and length of stay (LOS) were compared to 26 AAA patients undergoing EVR with bilateral femoral cutdowns before the percutaneous technique was available. Follow-up included duplex ultrasonography and clinical examination.

Results: Bilateral percutaneous closure of the femoral arteries was successful in 78 (82%) patients. Fifteen patients required arteriorrhaphy intraoperatively and 2 others within 24 hours. The failure rate was 20%, 0%, 3%, and 7% for the 20-F, 18-F, 16-F, and 14-F introducers, respectively. Blood loss was 400 mL (range 0–1800) in successful cases, 900 mL (range 0–3000) in failures (p<0.0001). One deep infection at the puncture site required thrombectomy and patchplasty; no other late complication occurred. There was no significant difference in operative time, blood loss, and LOS between patients treated with percutaneous EVR and those with primary femoral exposure.

Conclusions: Percutaneous transfemoral EVR of AAA using large-bore introducer sheaths is safe. More than three quarters of the patients avoid femoral cutdown. Late complications are rare.

Keywords: abdominal aortic aneurysm, endovascular repair, stent-graft, vascular closure device, percutaneous repair



© Copyright by International Society of Endovascular Specialists 2004